Search Results related to: control techniques focus 3n wiring and s
Select item to view details
| Part # | Manufacturer | Description | Stock |
|---|---|---|---|
| MOPLG240C | Eaton-Cutler Hammer | Available. Please Enquire. | |
| MOPLG24D | Eaton-Cutler Hammer | Available. Please Enquire. | |
| 8V1022.00-2 | B&R | Mains input voltage 3x 400 VAC to 480 VAC ±10% 3x 230 VAC ±10% Frequency 50 / 60 Hz ±4% Installed load Max. 3 kVA Inrush current at 400 VAC 4 A Switch-on interval >10 s Power dissipation at device nominal power without braking resistor Appr. 120W | Available. Please Enquire. |
| 8V1022.001-2 | B&R | Mains input voltage 3x 400 VAC to 480 VAC ±10% 3x 230 VAC ±10% Frequency 50 / 60 Hz ±4% Installed load Max. 3 kVA Inrush current at 400 VAC 4 A Switch-on interval >10 s Power dissipation at device nominal power without braking resistor App. 120W | Available. Please Enquire. |
| 8V1090.00-2 | B&R | Mains input voltage 3x 400 VAC to 480 VAC ±10% 3x 230 VAC ±10% Frequency 50 / 60 Hz ±4% Installed load Max. 10 kVA Inrush current at 400 VAC 7 A Switch-on interval >10 s Power dissipation at device nominal power without braking resistor App. 200W | Available. Please Enquire. |
| 8V1090.001-2 | B&R | Mains input voltage 3x 400 VAC to 480 VAC ±10% 3x 230 VAC ±10% Frequency 50 / 60 Hz ±4% Installed load Max. 10 kVA Inrush current at 400 VAC 7 A Switch-on interval >10 s Power dissipation at device nominal power without braking resistor Approx. 20 | Available. Please Enquire. |
| 8V1180.00-2 | B&R | Mains input voltage 3x 400 VAC to 480 VAC ±10% Frequency 50 / 60 Hz ±4% Installed load Max. 17 kVA Inrush current at 400 VAC 13 A Switch-on interval >10 s Power dissipation at device nominal power without braking resistor Approx. 500 W | Available. Please Enquire. |
| 8V1180.001-2 | B&R | Mains input voltage 3x 400 VAC to 480 VAC ±10% Frequency 50 / 60 Hz ±4% Installed load Max. 17 kVA Inrush current at 400 VAC 13 A Switch-on interval >10 s Power dissipation at device nominal power without braking resistor Approx. 500 W | Available. Please Enquire. |
| 8V128M.00-2 | B&R | Mains input voltage 3x 400 VAC to 480 VAC ±10% Frequency 50 / 60 Hz ±4% Installed load Max. 98 kVA Inrush current at 400 VAC 26 A Switch-on interval >10 s Power dissipation at device nominal power without braking resistor Approx. 3200 W | Available. Please Enquire. |
| 8V1320.00-2 | B&R | Mains input voltage 3x 400 VAC to 480 VAC ±10% Frequency 50 / 60 Hz ±4% Installed load Max. 30 kVA Inrush current at 400 VAC 13 A Switch-on interval >10 s Power dissipation at device nominal power without braking resistor Approx. 800 W | Available. Please Enquire. |
| 8V1320.001-2 | B&R | Mains input voltage 3x 400 VAC to 480 VAC ±10% Frequency 50 / 60 Hz ±4% Installed load Max. 30 kVA Inrush current at 400 VAC 13 A Switch-on interval >10 s Power dissipation at device nominal power without braking resistor Approx. 800 W | Available. Please Enquire. |
| 80VD100PD.C000-01 | B&R | Input voltage 24 VDC ±25% Voltage monitoring Yes nput voltage 24 to 64 VDC ±25% Inrush current Max. 10 A Idle (no motor powered) 0.5 W Continuous power consumption 1.31 kW | Available. Please Enquire. |
| 80VD100PD.C000-14 | B&R | 80VD100PD.C000-14 DESCRIPTION: Control for 2 servo motors 2 EnDat 2.2 interfaces 2 trigger inputs Connection for motor holding brake Enable input 1 digital input 24 VDC, sink 2 digital outputs 24 VDC, 1 A | Available. Please Enquire. |
| KPS-600-20 | Kuka | Available. Please Enquire. | |
| KPS-600-20-REL | Kuka | Available. Please Enquire. | |
| KPS600-20-ESC | Kuka | Available. Please Enquire. | |
| KSD1-08 | Kuka | Available. Please Enquire. | |
| KSD1-16 | Kuka | Available. Please Enquire. | |
| KSD1-32 | Kuka | Available. Please Enquire. | |
| KSD1-48 | Kuka | Available. Please Enquire. |